1.
Rev. bras. cardiol. invasiva ; 18(2): 204-211, jun. 2010. ilus
Article in Portuguese | LILACS | ID: lil-559928

ABSTRACT

Introdução: Nos últimos 30 anos, vários dispositivos têm sido utilizados para o fechamento percutâneo dos canais arteriais patentes. O Amplatzer Duct Occluder II (ADO II) foi desenvolvido para atender aos canais pequenos e moderados, com duplo disco e menor perfil, simplificando o implante sem perder a eficácia e a segurança. O objetivo deste estudo é discutir aspectos técnicos do uso da nova prótese e apresentar a experiência do grupo no uso desse dispositivo. Método: Análise dos registros de pacientes portadores de canal arterial patente submetidos a fechamento percutâneo com a prótese ADO II, no período de setembro de 2009 a março de 2010, identificados por ecocardiogramas transtorácicos. Resultados: Foram selecionados 8 pacientes. Os pesos variaram de 8 kg a 78 kg (38,8 + 24,1 kg). Quatro canais eram do tipo E, três eram do tipo A, e um, do tipo C. O implante foi possível em todos os casos. As próteses utilizadas foram 5-6 em três casos, 5-4 em dois casos, e 4-6, 6-4 e 6-6 uma vez cada. Apenas um caso apresentou fluxo residual, sem jato, imediatamente após o fechamento, que desapareceu no primeiro ecocardiograma transtorácico de controle na primeira semana de seguimento. Não houve óbito ou complicações em nenhum caso. Conclusão: A prótese ADO II mostrou-se segura e eficaz, mesmo em lactentes. A abordagem retrógrada torna o procedimento mais rápido e fácil. As taxas de oclusão são comparáveis às do ADO I. Estudos com maior número de pacientes e seguimento mais longo são necessários para estabelecer a segurança e a eficácia do dispositivo em crianças menores.


Background: Over the last 30 years, several devices have been used for the percutaneous closure of the patent ductus arteriosus (PDA). The Amplatzer Duct Occluder II (ADO II) was developed to address small to moderate PDAs with a double disk and lower profile, which makes implantationeasier, without loosing efficacy and safety. The objective of this study is to discuss the technical aspects of this novel prosthesis and present the group’s experience with the use of this device. Method: From September/2009 to March/2010, the records of patients with PDAs undergoing percutaneousclosure with the ADO II prosthesis which had been diagnosed by transthoracic echocardiograms were analyzed. Results: Eight patients were selected. Weight ranged from 8 kg to 78 kg (38.8 + 24.1 kg). Four PDAs were typeE, three were type A and one was type C. Implant was feasible in all cases. The prosthesis used were 5-6 in threecases, 5-4 in two, and 4-6, 6-4 and 6-6 in one case each. Only one patient presented residual flow without a jet immediately after closure, which disappeared in the first followuptransthoracic echocardiogram within the first week after procedure. There were no deaths or procedure-relatedcomplications. Conclusion: The ADO II device proved to be safe and effective, even in infants. The retrograde approach made the procedure fast and easy. Occlusion rates are comparable to the ones obtained with ADO I. Furtherstudies with a larger patient sample and longer follow-up times are required to establish the device’s safety and efficacy in smaller children.


Subject(s)
Humans , Heart Defects, Congenital , Cardiac Catheterization/trends , Heart Valve Prosthesis , Ductus Arteriosus , Echocardiography , Prospective Studies
2.
In. Sousa, Amanda GMR; Piegas, Leopoldo S; Sousa, J Eduardo MR. Série Monografias Dante Pazzanese. Rio de Janeiro, Revinter, 2001. p.34, ilus, ilus.
Non-conventional in Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1069405

ABSTRACT

A anestesia para cateterismo cardíaco em crianças requer um plano de correta conduçaõ anestésica, pois, por ser uma técnica potencialmente perigosa, precisa produzir resultados consistentes, de alta qualidade e precisão.Muitos dos recém-nascidos que nescessitam se submeter a estudos hemodinâmicos e angiográficos estão muito doentes, com severa cianose ou função cardíaca prejudicada. Em qualquer evento, o fator limitante imediato de sua sobrevivência é, comumente, o fornecimento de oxigênio para os tecidos. Em muitas dessas crianças, a distribuição não aumenta significativamente, nem mesmo com admnistração de oxigênio a 100%...


Subject(s)
Anesthesia/adverse effects , Anesthesia/methods , Anesthesia/trends , Cardiac Catheterization/trends , Oxygenation